Reliability assessment of microgrid with renewable generation and prioritized loads
AI-generated Key Points
- The paper focuses on reliability assessment of microgrids with renewable generation and prioritized loads
- Microgrids are key components of smart grids and allow for integration of distributed energy resources (DER)
- A hybrid analytical-simulation method is proposed to evaluate the reliability of microgrids with distributed RES
- Results show enhanced reliability in the presence of microgrid topology, especially for highest priority load
- Sensitivity analysis is performed to understand effects of microgrid islanding failure
- Methodology is applied to a modified version of a distribution system connected to bus 5 of Roy Billinton test system
- Detailed information provided on solar output power calculations and reliability indices used for evaluating customer load points in a distribution system
- Study contributes valuable insights into assessing and enhancing the reliability of microgrids with renewable generation and prioritized loads.
Authors: O. A. Ansari, N. Safar, C. Y. Chung
Abstract: With the increase in awareness about the climate change, there has been a tremendous shift towards utilizing renewable energy sources (RES). In this regard, smart grid technologies have been presented to facilitate higher penetration of RES. Microgrids are the key components of the smart grids. Microgrids allow integration of various distributed energy resources (DER) such as the distributed generation (DGs) and energy storage systems (ESSs) into the distribution system and hence remove or delay the need for distribution expansion. One of the crucial requirements for utilities is to ensure that the system reliability is maintained with the inclusion of microgrid topology. Therefore, this paper evaluates the reliability of a microgrid containing prioritized loads and distributed RES through a hybrid analytical-simulation method. The stochasticity of RES introduces complexity to the reliability evaluation. The method takes into account the variability of RES through Monte- Carlo state sampling simulation. The results indicate the reliability enhancement of the overall system in the presence of the microgrid topology. In particular, the highest priority load has the largest improvement in the reliability indices. Furthermore, sensitivity analysis is performed to understand the effects of the failure of microgrid islanding in the case of a fault in the upstream network.
Ask questions about this paper to our AI assistant
You can also chat with multiple papers at once here.
Assess the quality of the AI-generated content by voting
Score: 0
Why do we need votes?
Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.
The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.
Similar papers summarized with our AI tools
Navigate through even more similar papers through a
tree representationLook for similar papers (in beta version)
By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.
Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.