Phase-Apodized-Pupil Lyot Coronagraphs for Arbitrary Telescope Pupils

Authors: Emiel H. Por

arXiv: 1908.02585v1 - DOI (astro-ph.IM)
16 pages, 11 figures, accepted for publication in ApJ
AI-generated keywords: PAPLC APLC APP Exoplanets Optimization

AI-generated Key Points

⚠The license of the paper does not allow us to build upon its content and the key points are generated using the paper metadata rather than the full article.

  • The Phase-Apodized-Pupil Lyot Coronagraph (PAPLC) combines two coronagraphs to improve imaging of exoplanets.
  • A numerical optimization method is presented to obtain globally-optimal solutions for the phase apodizers for arbitrary telescope pupils.
  • PAPLCs with annular focal-plane masks and point-symmetric dark zones perform similarly to their corresponding APLCs.
  • With a knife-edge focal-plane mask and one-sided dark zones, PAPLC yields inner working angles as close as $1.4\lambda/D$ at contrasts of $10^{-10}$ and maximum post-coronagraphic throughput of more than 75% for telescope apertures with central obscurations up to 30%.
  • Designs optimized for the VLT/SPHERE instrument and LUVOIR-A aperture demonstrate that even realistic telescope pupils can retain performance when using knife edge PAPLCs.
  • This research provides an important step towards improving our ability to detect exoplanets by enhancing imaging capabilities through advanced coronagraph technology.
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Abstract: The phase-apodized-pupil Lyot coronagraph (PAPLC) is a pairing of the apodized-pupil Lyot coronagraph (APLC) and the apodizing phase plate (APP) coronagraph. We describe a numerical optimization method to obtain globally-optimal solutions for the phase apodizers for arbitrary telescope pupils, based on the linear map between complex-amplitude transmission of the apodizer and the electric field in the post-coronagraphic focal plane. PAPLCs with annular focal-plane masks and point-symmetric dark zones perform analogous to their corresponding APLCs. However with a knife-edge focal-plane mask and one-sided dark zones, the PAPLC yields inner working angles as close as $1.4\lambda/D$ at contrasts of $10^{-10}$ and maximum post-coronagraphic throughput of >75% for telescope apertures with central obscurations of up to 30%. We present knife-edge PAPLC designs optimized for the VLT/SPHERE instrument and the LUVOIR-A aperture. These designs show that the knife-edge PAPLC retains its performance, even for realistic telescope pupils with struts, segments and non-circular outer edges.

Submitted to arXiv on 07 Aug. 2019

Tools for this paper

Explain it differently 3 free rewrites left today
Export BibTeX · RIS (Zotero, Mendeley, EndNote) · Markdown (Notion, Obsidian) · Premium
Citation alerts Premium
For journalists Press kit and hype check Premium

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

⚠The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 1908.02585v1

⚠This paper's license doesn't allow us to build upon its content and the summarizing process is here made with the paper's metadata rather than the article.

  • Comprehensive Summary
  • Key points
  • Layman's Summary
  • Blog article
The Phase-Apodized-Pupil Lyot Coronagraph (PAPLC) combines the apodized-pupil Lyot coronagraph (APLC) and the apodizing phase plate (APP) coronagraph to improve imaging of exoplanets. In this study, a numerical optimization method is presented to obtain globally-optimal solutions for the phase apodizers for arbitrary telescope pupils. The method is based on the linear map between complex-amplitude transmission of the apodizer and the electric field in the post-coronagraphic focal plane. PAPLCs with annular focal-plane masks and point-symmetric dark zones perform similarly to their corresponding APLCs. However, with a knife-edge focal-plane mask and one-sided dark zones, PAPLC yields inner working angles as close as $1.4\lambda/D$ at contrasts of $10^{-10}$ and maximum post-coronagraphic throughput of more than 75% for telescope apertures with central obscurations up to 30%. The authors present designs optimized for the VLT/SPHERE instrument and LUVOIR-A aperture that demonstrate that even realistic telescope pupils with struts, segments, and noncircular outer edges can retain performance when using knife edge PAPLCs. This research provides an important step towards improving our ability to detect exoplanets by enhancing imaging capabilities through advanced coronagraph technology.

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

⚠The license of this specific paper does not allow us to build upon its content and the summarizing tools will be run using the paper metadata rather than the full article. However, it still does a good job, and you can also try our tools on papers with more open licenses.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.