Molecular sieve vacuum swing adsorption purification and radon reduction system for gaseous dark matter and rare-event detectors

AI-generated keywords: directional dark matter experiments SF6 contaminant gases molecular sieve gas recycling system

AI-generated Key Points

  • SF6 is an ideal target gas for directional dark matter experiments due to its unique properties.
  • Contaminant gases such as radon, water, oxygen, and nitrogen need to be effectively removed when using SF6 to prevent unwanted background events and loss of detector gas gain.
  • A novel molecular sieve (MS) based gas recycling system has been developed for the simultaneous removal of radon and common pollutants from SF6.
  • The system utilizes Vacuum Swing Adsorption (VSA) technique for continuous, long-term operation and minimizes the amount of gas required in experiments.
  • Low-radioactive MS materials like type 5A have been introduced to reduce radon emanation significantly compared to commercial counterparts.
  • MS types 3A and 4A successfully absorb common pollutants and help mitigate against gain deterioration while recycling the target gas.
  • Radon activity within the TPC detector was reduced substantially with an upper limit of less than 7.2 mBq at a 95% confidence level (C.L.).
  • A ThGEM-based TPC detector setup was used to demonstrate the effectiveness of the gas system in maintaining stable detector operation over extended periods.
  • The study provides a comprehensive solution for purifying SF6 gas in dark matter experiments by removing contaminants and minimizing background events, enhancing detector performance, and ensuring reliable data collection for future research endeavors.
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: R. R. Marcelo Gregorio, N. J. C. Spooner, F. Dastgiri, A. C. Ezeribe, G. Lane, A. G. McLean, K. Miuchi, H. Ogawa

arXiv: 2312.07720v2 - DOI (physics.ins-det)
License: CC BY 4.0

Abstract: In the field of directional dark matter experiments, SF6 has emerged as an ideal target gas. A critical challenge with this gas, and with other proposed gases, is the effective removal of contaminant gases. This includes radon which produce unwanted background events, but also common pollutants such as water, oxygen, and nitrogen, which can capture ionisation electrons, resulting in loss of detector gas gain over time. We present here a novel molecular sieve (MS) based gas recycling system for the simultaneous removal of both radon and common pollutants from SF6. The apparatus has the additional benefit of minimising gas required in experiments and utilises a Vacuum Swing Adsorption (VSA) technique for continuous, long-term operation. The gas system's capabilities were tested with a 100 L low-pressure SF6 Time Projection Chamber (TPC) detector. For the first time, we present a newly developed low-radioactive MS type 5A. This material was found to emanate radon at 98% less per radon captured compared to commercial counterparts, the lowest known MS emanation at the time of writing. Consequently, the radon activity in the TPC detector was reduced, with an upper limit of less than 7.2 mBq at a 95% confidence level (C.L.). Incorporation of MS types 3A and 4A to absorb common pollutants was found successfully to mitigate against gain deterioration while recycling the target gas.

Submitted to arXiv on 12 Dec. 2023

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2312.07720v2

In the field of directional dark matter experiments, SF6 has emerged as an ideal target gas due to its unique properties. A critical challenge in using SF6 and other proposed gases is effectively removing contaminant gases such as radon, water, oxygen, and nitrogen. These contaminants can lead to unwanted background events and loss of detector gas gain over time. To address this issue, a novel molecular sieve (MS) based gas recycling system has been developed for the simultaneous removal of both radon and common pollutants from SF6. This innovative apparatus not only minimizes the amount of gas required in experiments but also utilizes a Vacuum Swing Adsorption (VSA) technique for continuous, long-term operation. The capabilities of this gas system were tested with a 100 L low-pressure SF6 Time Projection Chamber (TPC) detector. For the first time, a newly developed low-radioactive MS type 5A was introduced which significantly reduced radon emanation compared to commercial counterparts. The incorporation of MS types 3A and 4A proved successful in absorbing common pollutants and mitigating against gain deterioration while recycling the target gas. The reduction in radon activity within the TPC detector was substantial with an upper limit of less than 7.2 mBq at a 95% confidence level (C.L.). Additionally, a ThGEM-based TPC detector setup was utilized for performance testing to demonstrate the effectiveness of the gas system in maintaining stable detector operation over extended periods. Overall, this study presents a comprehensive solution for purifying SF6 gas used in dark matter experiments by effectively removing contaminants and minimizing background events. The development of low-radioactive MS materials offers promising advancements in enhancing detector performance and ensuring reliable data collection for future research endeavors in this field.
Created on 30 Nov. 2024

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.