Objective assessment of corneal transparency in the clinical setting with standard SD-OCT devices
Auteurs : Maëlle Vilbert, Romain Bocheux, Cristina Georgeon, Vincent Borderie, Pascal Pernot, Kristina Irsch, Karsten Plamann
Résumé : PURPOSE: To develop an automated algorithm allowing extraction of quantitative corneal transparency parameters from clinical spectral-domain OCT images. To establish a representative dataset of normative transparency values from healthy corneas. METHODS: SD-OCT images of 83 normal corneas (ages 22-50 years) from a standard clinical device (RTVue-XR Avanti, Optovue Inc.) were processed. A pre-processing procedure is applied first, including a derivative approach and a PCA-based correction mask, to eliminate common central artifacts (i.e., apex-centered column saturation artifact and posterior stromal artifact) and enable standardized analysis. The mean intensity stromal-depth profile is then extracted over a 6-mm-wide corneal area and analyzed according to our previously developed method deriving quantitative transparency parameters related to the physics of light propagation in tissues, notably tissular heterogeneity (Birge ratio; $B_r$), followed by the photon mean-free path ($l_s$) in homogeneous tissues (i.e., $B_r \sim 1$). RESULTS: After confirming stromal homogeneity ($B_r < 10$, IDR: 1.9-5.1), we measured a median $l_s$ of 570 $\mu$m (IDR: 270-2400 $\mu$m). Considering corneal thicknesses, this may be translated into a median fraction of transmitted (coherent) light $T_{coh(stroma)}$ of 51$\%$ (IDR: 22-83$\%$). No statistically significant correlation between transparency and age or thickness was found. CONCLUSIONS: Our algorithm provides robust and quantitative measurement of corneal transparency from standard clinical SD-OCT images. It yields lower transparency values than previously reported, which may be attributed to our method being exclusively sensitive to spatially coherent light. Excluding images with central artifacts wider than 300 $\mu$m also raises our median $T_{coh(stroma)}$ to 70$\%$ (IDR: 34-87$\%$).
Explorez l'arbre d'article
Cliquez sur les nœuds de l'arborescence pour être redirigé vers un article donné et accéder à leurs résumés et assistant virtuel
Recherchez des articles similaires (en version bêta)
En cliquant sur le bouton ci-dessus, notre algorithme analysera tous les articles de notre base de données pour trouver le plus proche en fonction du contenu des articles complets et pas seulement des métadonnées. Veuillez noter que cela ne fonctionne que pour les articles pour lesquels nous avons généré des résumés et que vous pouvez le réexécuter de temps en temps pour obtenir un résultat plus précis pendant que notre base de données s'agrandit.