Design and Simulation of a Steam Turbine Generator using Observer Based and LQR Controllers

AI-generated keywords: Steam turbine generator Observer-based controller Linear quadratic regulator (LQR) controller Efficiency Voltage generation

AI-generated Key Points

  • Modeling, design, and analysis of a steam turbine generator using Matlab/Simulink Toolbox
  • Initial analysis shows open-loop system efficiency of 76.92%
  • Two controllers proposed: observer-based controller and linear quadratic regulator (LQR) controller
  • Comparison between controllers to identify better performance improvement for generating a 220 DC volt output
  • Simulation results show observer-based controller has smaller percentage overshoot and minimum settling time compared to LQR controller and open-loop system
  • Observer-based controller demonstrates superior performance improvement compared to LQR controller
  • Research provides insights into improving steam turbine generator performance through advanced control strategies
  • Importance of utilizing observer-based controllers for better efficiency and voltage generation in steam turbine systems
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Mustefa Jibril, Messay Tadese, Eliyas Alemayehu Tadese

License: CC BY 4.0

Abstract: Steam turbine generator is an electromechanical system which converts heat energy to electrical energy. In this paper, the modeling, design and analysis of a simple steam turbine generator have done using Matlab/Simulink Toolbox. The open loop system have been analyzed to have an efficiency of 76.92 %. Observer based & linear quadratic regulator (LQR) controllers have been designed to improve the generating voltage. Comparison of this two proposed controllers have been done for increasing the performance improvement to generate a 220 Dc volt. The simulation result shows that the steam turbine generator with observer based controller has a small percentage overshoot with minimum settling time than the steam turbine generator with LQR controller and the open loop system. Finally, the steam turbine generator with observer based controller shows better improvement in performance than the steam turbine generator with LQR controller.

Submitted to arXiv on 29 Aug. 2020

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2009.06714v1

Title: Design and Simulation of a Steam Turbine Generator using Observer Based and LQR Controllers Authors: Mustefa Jibril, Messay Tadese, Eliyas Alemayehu Tadese Affiliations1. School of Electrical & Computer Engineering, Dire Dawa Institute of Technology, Dire Dawa, Ethiopia 2. School of Electrical & Computer Engineering, Dire Dawa Institute of Technology, Dire Dawa, Ethiopia 3. Faculty of Electrical & Computer Engineering, Jimma Institute of Technology, Jimma, Ethiopia Email: [email protected] AbstractThe paper presents the modeling , design , and analysis of a simple steam turbine generator using Matlab/Simulink Toolbox. The objective is to convert heat energy into electrical energy efficiently. The open-loop system is initially analyzed and found to have an efficiency of 76.92%. To improve the generating voltage and overall performance , observer-based and linear quadratic regulator (LQR) controllers are designed and compared. SummarySteam turbine generators play a crucial role in converting heat energy into electrical energy in various applications. In this study conducted by Mustefa Jibril et al., the authors focus on the modeling , design , and analysis of a steam turbine generator using Matlab/Simulink Toolbox. The initial analysis involves studying the open-loop system's efficiency which is determined to be 76.92%. To enhance the generating voltage and overall performance , two different controllers are proposed: observer-based controller and linear quadratic regulator (LQR) controller. The comparison between these two controllers aims to identify which one provides better performance improvement for generating a 220 DC volt output. Through simulation results obtained from Matlab/Simulink Toolbox experiments, it is observed that the steam turbine generator with an observer-based controller exhibits a smaller percentage overshoot with minimum settling time compared to both the LQR controller and the open-loop system. The findings of the study indicate that the steam turbine generator with an observer-based controller demonstrates superior performance improvement compared to the LQR controller. This suggests that the observer-based controller is more effective in enhancing the generating voltage and overall efficiency of the steam turbine generator. In conclusion, this research provides valuable insights into improving the performance of steam turbine generators through the implementation of advanced control strategies. The results highlight the significance of utilizing observer-based controllers for achieving better efficiency and voltage generation in steam turbine systems. Further studies can be conducted to explore additional control techniques and optimize various parameters for even greater performance enhancement.
Created on 01 Feb. 2024

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.