Deep learning-enabled multiplexed point-of-care sensor using a paper-based fluorescence vertical flow assay

AI-generated keywords: Point-of-care Fluorescence Vertical Flow Assay Neural Networks Acute Cardiac Injury Diagnostics

AI-generated Key Points

The license of the paper does not allow us to build upon its content and the key points are generated using the paper metadata rather than the full article.

  • The paper presents a novel point-of-care serodiagnosis assay that can simultaneously quantify three biomarkers of acute cardiac injury.
  • The assay employs a paper-based fluorescence vertical flow platform (fxVFA) that is processed by a low-cost mobile reader and trained neural networks to quantify the target biomarkers within less than 15 minutes of test time, using only 50 microliters of serum sample per patient.
  • The fxVFA platform was validated using human serum samples to quantify three cardiac biomarkers: myoglobin, creatine kinase-MB (CK-MB), and heart-type fatty acid binding protein (FABP).
  • The platform achieved less than 0.52 ng/mL limit-of-detection for all three biomarkers with minimal cross-reactivity.
  • The concentration quantification of the biomarkers was tested using 46 individually activated cartridges which showed high correlation with the ground truth concentrations for all three biomarkers achieving more than 0.9 linearity and less than 15% coefficient of variation.
  • This multiplexed computational fxVFA has competitive performance along with its inexpensive paper-based design and handheld footprint, making it an effective point-of-care sensor platform that could expand access to diagnostics in resource limited settings.
  • This technology can be used for early detection and management of acute cardiac injuries which is essential in improving patient outcomes.
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Artem Goncharov, Hyou-Arm Joung, Rajesh Ghosh, Gyeo-Re Han, Zachary S. Ballard, Quinn Maloney, Alexandra Bell, Chew Tin Zar Aung, Omai B. Garner, Dino Di Carlo, Aydogan Ozcan

arXiv: 2301.10934v1 - DOI (physics.med-ph)
17 Pages, 6 Figures

Abstract: We demonstrate multiplexed computational sensing with a point-of-care serodiagnosis assay to simultaneously quantify three biomarkers of acute cardiac injury. This point-of-care sensor includes a paper-based fluorescence vertical flow assay (fxVFA) processed by a low-cost mobile reader, which quantifies the target biomarkers through trained neural networks, all within <15 min of test time using 50 microliters of serum sample per patient. This fxVFA platform is validated using human serum samples to quantify three cardiac biomarkers, i.e., myoglobin, creatine kinase-MB (CK-MB) and heart-type fatty acid binding protein (FABP), achieving less than 0.52 ng/mL limit-of-detection for all three biomarkers with minimal cross-reactivity. Biomarker concentration quantification using the fxVFA that is coupled to neural network-based inference is blindly tested using 46 individually activated cartridges, which showed a high correlation with the ground truth concentrations for all three biomarkers achieving > 0.9 linearity and < 15 % coefficient of variation. The competitive performance of this multiplexed computational fxVFA along with its inexpensive paper-based design and handheld footprint make it a promising point-of-care sensor platform that could expand access to diagnostics in resource-limited settings.

Submitted to arXiv on 26 Jan. 2023

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2301.10934v1

This paper's license doesn't allow us to build upon its content and the summarizing process is here made with the paper's metadata rather than the article.

The paper titled "Deep learning-enabled multiplexed point-of-care sensor using a paper-based fluorescence vertical flow assay" presents a novel point-of-care serodiagnosis assay that can simultaneously quantify three biomarkers of acute cardiac injury. The assay employs a paper-based fluorescence vertical flow platform (fxVFA) that is processed by a low-cost mobile reader and trained neural networks to quantify the target biomarkers within less than 15 minutes of test time, using only 50 microliters of serum sample per patient. The fxVFA platform was validated using human serum samples to quantify three cardiac biomarkers: myoglobin, creatine kinase-MB (CK-MB), and heart-type fatty acid binding protein (FABP). The platform achieved less than 0.52 ng/mL limit-of-detection for all three biomarkers with minimal cross-reactivity. The concentration quantification of the biomarkers was tested using 46 individually activated cartridges which showed high correlation with the ground truth concentrations for all three biomarkers achieving more than 0.9 linearity and less than 15% coefficient of variation. This multiplexed computational fxVFA has competitive performance along with its inexpensive paper-based design and handheld footprint, making it an effective point-of-care sensor platform that could expand access to diagnostics in resource limited settings. Furthermore, this technology can be used for early detection and management of acute cardiac injuries which is essential in improving patient outcomes. Overall, this study provides an innovative solution to address the challenges associated with current diagnostic methods for acute cardiac injuries and highlights the potential impact on healthcare delivery in resource limited settings.
Created on 07 Apr. 2023

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

The license of this specific paper does not allow us to build upon its content and the summarizing tools will be run using the paper metadata rather than the full article. However, it still does a good job, and you can also try our tools on papers with more open licenses.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.