Pelphix: Surgical Phase Recognition from X-ray Images in Percutaneous Pelvic Fixation

AI-generated keywords: Surgical phase recognition

AI-generated Key Points

  • Pelphix is an innovative approach to surgical phase recognition (SPR) for X-ray-guided percutaneous pelvic fracture fixation
  • Pelphix models the workflow of pelvic fracture fixation at four levels: corridor, activity, view, and frame value
  • Core innovation lies in using machine learning techniques and a transformer model for accurate regression of surgical phases
  • Achieves promising results with average accuracy rates of 93.8% on simulated sequences and 67.57% in cadaveric studies
  • Demonstrates up to 88% accuracy in identifying the target corridor in real X-ray data
  • Shows impressive accuracy range of 86.3% to 98.2% across different granularity levels in simulated sequences
  • Cadaver study validates effectiveness and ability to generalize from simulated to real scenarios
  • Areas for improvement include refining screw insertion depth variability based on anatomy and addressing sampling biases
  • Represents a significant advancement in SPR capabilities for X-ray-guided surgeries with potential applications in orthopedic procedures, angiography interventions, and interventional radiology practices
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Benjamin D. Killeen, Han Zhang, Jan Mangulabnan, Mehran Armand, Russel H. Taylor, Greg Osgood, Mathias Unberath

License: CC BY 4.0

Abstract: Surgical phase recognition (SPR) is a crucial element in the digital transformation of the modern operating theater. While SPR based on video sources is well-established, incorporation of interventional X-ray sequences has not yet been explored. This paper presents Pelphix, a first approach to SPR for X-ray-guided percutaneous pelvic fracture fixation, which models the procedure at four levels of granularity -- corridor, activity, view, and frame value -- simulating the pelvic fracture fixation workflow as a Markov process to provide fully annotated training data. Using added supervision from detection of bony corridors, tools, and anatomy, we learn image representations that are fed into a transformer model to regress surgical phases at the four granularity levels. Our approach demonstrates the feasibility of X-ray-based SPR, achieving an average accuracy of 93.8% on simulated sequences and 67.57% in cadaver across all granularity levels, with up to 88% accuracy for the target corridor in real data. This work constitutes the first step toward SPR for the X-ray domain, establishing an approach to categorizing phases in X-ray-guided surgery, simulating realistic image sequences to enable machine learning model development, and demonstrating that this approach is feasible for the analysis of real procedures. As X-ray-based SPR continues to mature, it will benefit procedures in orthopedic surgery, angiography, and interventional radiology by equipping intelligent surgical systems with situational awareness in the operating room.

Submitted to arXiv on 18 Apr. 2023

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2304.09285v1

, , , , Pelphix is an innovative approach to surgical phase recognition (SPR) specifically designed for X-ray-guided percutaneous pelvic fracture fixation. While video sources have been extensively used in SPR, the integration of interventional X-ray sequences has been largely unexplored. Pelphix addresses this gap by modeling the complex workflow of pelvic fracture fixation at four distinct levels of granularity: corridor, activity, view, and frame value. This is achieved through a Markov process and meticulous annotation of training data, leveraging added supervision from the detection of bony corridors, tools, and anatomy. The core innovation of Pelphix lies in its use of machine learning techniques to learn image representations that are then fed into a transformer model for accurate regression of surgical phases at multiple granularity levels. The results obtained from this approach are promising, with an average accuracy rate of 93.8% on simulated sequences and 67.57% in cadaveric studies across all granularity levels. Notably, Pelphix achieves up to 88% accuracy in identifying the target corridor in real X-ray data. In simulated sequences, Pelphix demonstrates impressive results with an accuracy range of 86.3% to 98.2% across different granularity levels, indicating strong potential for real-world scenarios. The cadaver study further validates Pelphix's effectiveness by demonstrating its ability to generalize from simulated to real scenarios through qualitative segmentation masks. While there were variations in accuracy rates across different phases and views during the cadaver study evaluation, overall performance was deemed satisfactory and indicative of Pelphix's viability as an SPR solution for X-ray-guided surgeries. The discussion highlights areas for improvement such as refining screw insertion depth variability based on anatomy and addressing sampling biases that may have influenced certain view representations. In conclusion, Pelphix represents a significant advancement in SPR capabilities for X-ray-guided surgeries. As this technology continues to evolve and mature, it holds immense promise for enhancing situational awareness within operating rooms during orthopedic procedures, angiography interventions, and interventional radiology practices.
Created on 10 Mar. 2025

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.