Magnetic fields inferred by Solar Orbiter: A comparison between SO/PHI-HRT and SDO/HMI

Authors: J. Sinjan, D. Calchetti, J. Hirzberger, F. Kahil, G. Valori, S. K. Solanki, K. Albert, N. Albelo Jorge, A. Alvarez-Herrero, T. Appourchaux, L. R. Bellot Rubio, J. Blanco Rodríguez, A. Feller, A. Gandorfer, D. Germerott, L. Gizon, J. M. Gómez Cama, L. Guerrero, P. Gutierrez-Marques, M. Kolleck, A. Korpi-Lagg, H. Michalik, A. Moreno Vacas, D. Orozco Suárez, I. Pérez-Grande, E. Sanchis Kilders, M. Balaguer Jiménez, J. Schou, U. Schühle, J. Staub, H. Strecker, J. C. del Toro Iniesta, R. Volkmer, J. Woch

arXiv: 2303.16771v1 - DOI (astro-ph.SR)
10 pages, 5 figures, accepted for publication in A&A; manuscript is a part of Astronomy & Astrophysics special issue: Solar Orbiter First Results (Nominal Mission Phase)

Abstract: The High Resolution Telescope (HRT) of the Polarimetric and Helioseismic Imager on board the Solar Orbiter spacecraft (SO/PHI) and the Helioseismic and Magnetic Imager (HMI) on board the Solar Dynamics Observatory (SDO) both infer the photospheric magnetic field from polarised light images. SO/PHI is the first magnetograph to move out of the Sun--Earth line and will provide unprecedented access to the Sun's poles. This provides excellent opportunities for new research wherein the magnetic field maps from both instruments are used simultaneously. We aim to compare the magnetic field maps from these two instruments and discuss any possible differences between them. We used data from both instruments obtained during Solar Orbiter's inferior conjunction on 7 March 2022. The HRT data were additionally treated for geometric distortion and degraded to the same resolution as HMI. The HMI data were re-projected to correct for the $3^{\circ}$ separation between the two observatories. SO/PHI-HRT and HMI produce remarkably similar line-of-sight magnetograms, with a slope coefficient of $0.97$, an offset below $1$ G, and a Pearson correlation coefficient of $0.97$. However, SO/PHI-HRT infers weaker line-of-sight fields for the strongest fields. As for the vector magnetic field, SO/PHI-HRT was compared to both the $720$-second and $90$-second HMI vector magnetic field: SO/PHI-HRT has a closer alignment with the $90$-second HMI vector. In the weak signal regime ($< 600$ G), SO/PHI-HRT measures stronger and more horizontal fields than HMI, very likely due to the greater noise in the SO/PHI-HRT data. In the strong field regime ($\gtrsim 600$ G), HRT infers lower field strengths but with similar inclinations (a slope of $0.92$) and azimuths (a slope of $1.02$). The slope values are from the comparison with the HMI $90$-second vector.

Submitted to arXiv on 29 Mar. 2023

Explore the paper tree

Click on the tree nodes to be redirected to a given paper and access their summaries and virtual assistant

Also access our AI generated Summaries, or ask questions about this paper to our AI assistant.

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.