AI summary · arXiv: 2303.13637v1 · cs.LG

Efficient and Direct Inference of Heart Rate Variability using Both Signal Processing and Machine Learning

Yuntong Zhang, Jingye Xu, Mimi Xie, Dakai Zhu, Houbing Song, Wei Wang
Original paper · DOI 10.1145/3580252.3586971 Submitted to arXiv on 23 Mar. 2023 Published in Proceedings of the 8th ACM/IEEE International Conference on Connected Health: Applications, Systems and Engineering Technologies (22 Jan. 2024) License: CC BY 4.0

How to read this summary? Illustrated guide

The essentials

  • Heart Rate Variability (HRV) is an important indicator of physical and mental health
  • Photoplethysmography (PPG) sensors can be used to infer HRV
  • Yuntong Zhang et al. collected a large dataset of PPG signals and HRV ground truth to address limitations of prior studies
  • They developed HRV models combining signal processing and machine learning for direct inference of HRV with errors between 3.5% to 25.7%
  • Decision Trees (DT) and Multi-level Perceptrons (MLP) are more suitable for small embedded devices with good accuracy
  • A new dataset containing three 2-hour-long PPG/ECG traces for one human subject performing various activities was collected
  • This study provides an efficient HRV inference methodology using both signal processing and machine learning techniques that can potentially enable the future use of PPG-based HRV monitoring in healthcare on small embedded devices with limited memory size requirements

Key points written by AI: they may contain errors, check them against the paper.

AI-generated keywords: HRV PPG ML Signal Processing Healthcare

Read further

  • Comprehensive Summary
  • Layman's Summary
  • Blog article
  • Original abstract
Heart Rate Variability (HRV) is a significant indicator of physical and mental health, measuring the variation of time between consecutive heartbeats. Recent research has shown that photoplethysmography (PPG) sensors can be used to infer HRV. To address the limitations of prior studies relying on signal processing or machine learning (ML), indirect inference of HRV, small datasets, and large ML models which restrict their applications to small embedded devices and potential use in healthcare, Yuntong Zhang et al. collected a large dataset of PPG signals and HRV ground truth. They developed HRV models combining signal processing and ML for direct inference of HRV which achieved errors between 3.5% to 25.7%, outperforming signal-processing-only and ML-only methods. The authors explored different ML models showing that Decision Trees (DT) and Multi-level Perceptrons (MLP) are more suitable for small embedded devices with good accuracy; DT models had an average error of 13.0% with less than 10KB size and inference time less than 10𝜇s while MLP models had an average error of 9.1% with less than 469KB size and inference time less than 1ms. Additionally, they collected a new dataset containing three 2-hour-long PPG/ECG traces for one human subject performing various activities such as work, sleeping, and sitting. This study provides an efficient HRV inference methodology using both signal processing and machine learning techniques that can potentially enable the future use of PPG-based HRV monitoring in healthcare on small embedded devices with limited memory size requirements.

Was this synthesis useful?

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

Figures and plots

Ask about a figure by number or use its question button to request visual analysis. Up to two figures and four image panels per question. Values read from plots are approximate; check the original data.

AI assistant instructions?

Tools for this paper

Explain it differently 1 free rewrite left today
Save to a collection Group papers in collections to compare them, chat with them and export them. Continue with Google Create a free account Log in

Advanced tools Premium

For researchers who follow a field closely: citation alerts, journal-club slides, version comparison and Zotero export. Discover Premium

Zotero Zotero guide
Citation alerts 4 papers already cite it: be emailed each new one. Citation alerts guide
Who works on it?

Among the 27 papers around this one, the name that comes back most: Yun-Tong Zhang (3 papers)

2 more people sign several of them. The full map adds their institutions and approaches, from the papers of the last years.

Continue with Google Create a free account: your first map is free
Weekly letter The latest letter of its field, "Artificial intelligence this week" of 23 November 2026: Artificial intelligence this week: The difference between looking right and getting it right · Receive one by email for free

Papers around this one

See them on a map

Ranked by how close their title and abstract are to this paper’s. Select some to read them together.

Closest papers

  1. Very close
    Lightweight Heart Rate Variability Estimation Using PPG Signals
    B. Brown, Chongzhou Fang · 2026 · IEEE International Symposium on Quality Electronic Design · Not summarized yet
    Abstract

    Heart rate variability (HRV) reflects the autonomic regulation of cardiac activity and serves as an important biomarker in clinical and physiological research, providing insights into stress, fatigue, and cardiovascular health. Traditionally, accurate HRV estimation relies on electrocardiogram (ECG) recordings, which require precise electrode placement and controlled measurement conditions. Although photoplethysmography (PPG) signals can also be used to estimate HRV, their accuracy is often reported to be suboptimal. In this work, we demonstrate that HRV estimation from PPG signals can be significantly improved by leveraging lightweight machine learning models. Our results show that the prop…

  2. Very close Cited by this paper A method it uses
    Evaluation of HRV estimation algorithms from PPG data using neural networks
    T. Wittenberg, R. Koch, N. Pfeiffer et al. · 2020 · Current Directions in Biomedical Engineering · cited 10 times · Not summarized yet
    Abstract

    Abstract Heart rate variability (HRV) is a powerful measure to gain information on the activation of the central nervous system and is thus a strong indicator for the overall health and emotional state of a person. Currently, the gold standard for HRV analysis is the examination of R-peaks in electrocardiograms (ECG), which requires a placement of electrodes on the torso. This is often impracticable, especially for the use in daily routines or 24/7 measurements. Photoplethysmograms (PPG) are an alternative to ECG assessment and are easier to acquire, e.g. by using fitness trackers or smart watches. Nevertheless, PPG data is more susceptible to motion artifacts. Hence, goal of this work is to…

  3. Very close
    Ultra-Short Term Heart Rate Variability Estimation Using PPG and End-to-End Deep Learning
    Wei-Nan Wang, L. Najafizadeh · 2024 · Asilomar Conference on Signals, Systems and Computers · cited 1 time · Not summarized yet
    Abstract

    Heart rate variability (HRV) is a marker that could be indicative of critical health events. Continuous monitoring of HRV in intensive care unit (ICU) holds great promise for improving patient's prognosis. However, current methods requiring measuring HRV using electrocardiogram (ECG) sensors over an extended duration offer limited applicability for continuous and disturbance-free HRV tracking in ICU cases. This underscores the need for new methods that can rapidly measure HRV from a single unobtrusive sensor. Here, we explore the feasibility of using an end-to-end deep learning model to enable real-time ultra-short term HRV (usHRV) estimation from 10-s segments of photoplethysmogram (PPG) si…

  4. Very close
    Photoplethysmograph-based time-frequency and machine learning applications on biomedical signal analysis for medical diagnosis
    Soumyadip Jana, P. Pal · 2025 · Indonesian Journal of Electrical Engineering and Computer Science · Not summarized yet
    Abstract

    Machine learning (ML) integration in biomedical signal processing and medical diagnosis has the potential to revolutionize healthcare by improving diagnostic accuracy. This paper focuses on the applications of different ML algorithms for analyzing real-time physiological data collected from Photoplethysmography (PPG) sensors. Heart rate variability (HRV) analysis using electrocardiography (ECG) signals makes the process longer and bulky. Therefore, this paper demonstrates the real-time generation of HRV signals using a simple, low-cost, and non-invasive PPG sensor which is further processed using the Arduino ATMEGA328P microcontroller and then interfaced to a PC for display to investigate th…

  5. Very close
    Hybrid CNN-LSTM Model for Evaluating Heart Rate Variability from Pulse-to-Pulse Intervals
    Alok Kumar Sharma, Shing-Hong Liu, Jia-Jung Wang et al. · 2025 · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · cited 2 times · Not summarized yet
    Abstract

    Heart rate variability (HRV) is a key marker of autonomic function and cardiovascular health. This study proposes a hybrid CNN-LSTM model to estimate ECG-derived R-R intervals (RRI) from Photoplethysmography (PPG) signals, enabling non-invasive HRV monitoring. Data from 19 subjects under controlled breathing conditions (6, 18, and 30 breaths per minute) were used to train and validate the model. Results show a high correlation between predicted and actual RRI, with mean absolute error (MAE) decreasing from 62.01 ms to 49.62 ms across subjects. While the model accurately captures HRV at lower breathing rates, frequency domain analysis reveals systematic underestimation of very low frequency (…

  6. Very close Cited by this paper A method it uses
    PPG-based Heart Rate Estimation with Efficient Sensor Sampling and Learning Models
    Yun-Tong Zhang, Jingye Xu, Mimi Xie et al. · 2022 · 2022 IEEE 24th Int Conf on High Performance Computing & Communications; 8th Int Conf on Data Science & Systems; 20th Int · cited 12 times · Not summarized yet
    Abstract

    Recent studies showed that Photoplethysmography (PPG) sensors embedded in wearable devices can estimate heart rate (HR) with high accuracy. However, despite of prior research efforts, applying PPG sensor based HR estimation to embedded devices still faces challenges due to the energy-intensive high-frequency PPG sampling and the resource-intensive machine-learning models. In this work, we aim to explore HR estimation techniques that are more suitable for lower-power and resource-constrained embedded devices. More specifically, we seek to design techniques that could provide high-accuracy HR estimation with low-frequency PPG sampling, small model size, and fast inference time. First, we show …

  7. Very close Cited by this paper A method it uses
    A Machine Learning Approach for Heart Rate Estimation from PPG Signal using Random Forest Regression Algorithm
    Shikder Shafiul Bashar, M. Miah, Abdul Karim et al. · 2019 · European Conference on Cognitive Ergonomics · cited 25 times · Not summarized yet
    Abstract

    In this paper, a new method is proposed to estimate the heart rate (HR) from wearable devices. A promising feature in today's world of HR monitoring is Photoplethysmography (PPG). However, during physical exercise HR estimation accuracy is seriously affected by noise and motion artifacts (MA). To reduce the effect of MA and estimate HR changes there are many conventional algorithms. Here, a new approach to estimate HR which is called multi-model machine learning approach (MMMLA) is shown. In this proposed algorithm, it firstly trains and tests the model for the different feature and different data set. Then it separates noisy and non-noisy data by K-means clustering. This lets the machine le…

  8. Very close Cited by this paper
    Heart rate variability estimation in photoplethysmography signals using Bayesian learning approach
    Ahmed Alqaraawi, Ahmad Alwosheel, A. Alasaad · 2016 · Healthcare technology letters · cited 59 times · Not summarized yet
    Abstract

    Heart rate variability (HRV) has become a marker for various health and disease conditions. Photoplethysmography (PPG) sensors integrated in wearable devices such as smart watches and phones are widely used to measure heart activities. HRV requires accurate estimation of time interval between consecutive peaks in the PPG signal. However, PPG signal is very sensitive to motion artefact which may lead to poor HRV estimation if false peaks are detected. In this Letter, the authors propose a probabilistic approach based on Bayesian learning to better estimate HRV from PPG signal recorded by wearable devices and enhance the performance of the automatic multi scale-based peak detection (AMPD) algo…

Prior work it builds on

  1. Close Used in depth by this paper A method it uses
    BioTranslator: Inferring R-Peaks from Ambulatory Wrist-Worn PPG Signal
    Luke R. Everson, Dwaipayan Biswas, Bram-Ernst Verhoef et al. · 2019 · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · cited 10 times · Not summarized yet
    Abstract

    Advancements in wireless sensor networks (WSN) technology and miniaturization of wearable sensors have enabled long-term continuous pervasive biomedical signal monitoring. Wrist-worn photoplethysmography (PPG) sensors have gained popularity given their form factor. However the signal quality suffers due to motion artifacts when used in ambulatory settings, making vital parameter estimation a challenging task. In this paper, we present a novel deep learning framework, BioTranslator, for computing the instantaneous heart rate (IHR), using wrist-worn PPG signals collected during physical activity. Using one-dimensional Convolution-Deconvolution Network, we translate a single channel PPG signal …

  2. Close A method it uses
    A 0.5V PPG-based Heart Rate and Variability Detection System
    Wala Saadeh, S. Aslam, Aminah Hina et al. · 2018 · Biomedical Circuits and Systems Conference · cited 21 times · Not summarized yet
    Abstract

    Heart Rate Variability (HRV) is a diagnostic and predictive tool for multiple health conditions. A Photoplethysmographic (PPG) based HRV detection system with a low-power readout together with an embedded feature extraction processor to measure heart rate (HR) and HRV is presented. The proposed system proposes a low power LED driver with novel clock bootstrapping switching. The LED current is digitally controlled for adjusting LED brightness using Pulse Density Modulation (PDM) with >90% efficiency. It also introduces a highly compact low power/low noise transimpedance amplifier for an input base current range (0.5nA-4.5µA). The proposed system eliminates the motion artifacts without the nee…

  3. Close A method it uses
    Deep Recurrent Neural Network for Extracting Pulse Rate Variability from Photoplethysmography During Strenuous Physical Exercise
    Ke Xu, Xin-Yu Jiang, Haoran Ren et al. · 2019 · Biomedical Circuits and Systems Conference · cited 25 times · Not summarized yet
    Abstract

    Pulse rate variability (PRV) extracted from photoplethysmography (PPG) signal is a promising surrogate for heart rate variability (HRV) and has shown its great potential in diagnosing cardiac dysfunctions and autonomic nervous system diseases. However, the accurate extraction of PRV during strenuous physical exercise faces enormous challenges due to PPG’s extreme vulnerability to motion artifacts. In this work, we introduce a deep recurrent neural network (RNN) based on bidirectional Long-Short Term Memory Network (biLSTM) for accurate PPG cardiac period segmentation. After that, three important indexes for PRV are calculated, which are peak intervals, pulse intervals, and instantaneous hear…

  4. Close A method it uses
    Design and Prototyping of a Wristband-Type Wireless Photoplethysmographic Device for Heart Rate Variability Signal Analysis
    M. Ghamari, C. Soltanpur, S. Cabrera et al. · 2016 · Annual International Conference of the IEEE Engineering in Medicine and Biology Society · cited 26 times · Not summarized yet
    Abstract

    Heart Rate Variability (HRV) signal analysis provides a quantitative marker of the Autonomic Nervous System (ANS) function. A wristband-type wireless photoplethysmographic (PPG) device was custom-designed to collect and analyze the arterial pulse in the wrist. The proposed device is comprised of an optical sensor to monitor arterial pulse, a signal conditioning unit to filter and amplify the analog PPG signal, a microcontroller to digitize the analog PPG signal, and a Bluetooth module to transfer the data to a smart device. This paper proposes a novel model to represent the PPG signal as the summation of two Gaussian functions. The paper concludes with a verification procedure for HRV signal…

  5. Close
    DeepHeart
    Xiang-Mao Chang, Gangkai Li, Guo-Liang Xing et al. · 2021 · ACM Trans. Sens. Networks · cited 37 times · Not summarized yet
    Abstract

    Heart rate (HR) estimation based on photoplethysmography (PPG) signals has been widely adopted in wrist-worn devices. However, the motion artifacts caused by the user’s physical activities make it difficult to get the accurate HR estimation from contaminated PPG signals. Although many signal processing methods have been proposed to address this challenge, they are often highly optimized for specific scenarios, making them impractical in real-world settings where a user may perform a wide range of physical activities. In this article, we propose DeepHeart, a new HR estimation approach that features deep-learning-based denoising and spectrum-analysis-based calibration. DeepHeart generates clea…

Papers that cite it

  1. Close
    A Comprehensive PPG-based Dataset for HR/HRV Studies
    Jing-Ye Xu, Yun-Tong Zhang, Wei Wang et al. · 2025 · IEEE International Conference on Healthcare Informatics · cited 4 times · Not summarized yet
    Abstract

    Heart rate (HR) and heart rate variability (HRV) are important vital signs for human physical and mental health. Recent research has demonstrated that photoplethysmography (PPG) sensors can infer HR and HRV. However, it is difficult to find a comprehensive PPG-based dataset for HR/HRV studies, especially for various study needs: multiple scenes, long-term monitoring, and multimodality (multiple PPG channels and extra acceleration data). In this study, we collected a comprehensive multimodal long-term dataset to address the gap of missing an all-in-one HR/HRV dataset (denoted as UTSA-PPG). We began by reviewing state-of-the-art datasets, emphasizing their strengths and limitations. Following …

  2. Related*
    Real-time intelligent on-device monitoring of heart rate variability with PPG sensors
    Jing-Ye Xu, Yun-Tong Zhang, Mimi Xie et al. · 2024 · Journal of systems architecture · cited 10 times · Not summarized yet
  3. Related*
    Research and application of machine learning methods for migraine attack prediction
    Viroslava Kapustynska · Not summarized yet
  4. Related
    A comprehensive survey on impact of applying various technologies on the internet of medical things
    Shorouk E. El-Deep, A. Abohany, Karam M. Sallam et al. · 2025 · Artificial Intelligence Review · cited 33 times · Not summarized yet
    Abstract

    This paper explores the transformative impact of the Internet of Medical Things (IoMT) on healthcare. By integrating medical equipment and sensors with the internet, IoMT enables real-time monitoring of patient health, remote patient care, and individualized treatment plans. IoMT significantly improves several healthcare domains, including managing chronic diseases, patient safety, and drug adherence, resulting in better patient outcomes and reduced expenses. Technologies like blockchain, Artificial Intelligence (AI), and cloud computing further boost IoMT’s capabilities in healthcare. Blockchain enhances data security and interoperability, AI analyzes massive volumes of health data to find …

How are these papers found?

We compare the title and abstract of this paper with those of every paper summarized on this site, and with the papers Semantic Scholar recommends, those it cites and those citing it (for a much-cited paper, its most recent citations and, from OpenAlex, the most cited ones). Among the prior work and the follow-ups, the papers that use each other in depth, a method it uses and the much-cited follow-ups come a little higher. The levels (very close, close, related) come from the similarity of the texts, not from a judgment of quality; * marks a paper without an abstract, compared by its title. The sentence under a paper is written by an AI from the two abstracts: check it in the papers. A paper marked not relevant by three readers leaves the list.

Updated on 6 November 2026.

The illustrated guide to the papers around a paper

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.