Approaching Test Time Augmentation in the Context of Uncertainty Calibration for Deep Neural Networks

AI-generated keywords: Machine Learning Uncertainty Calibration Test Time Augmentation M-ATTA V-ATTA

AI-generated Key Points

The license of the paper does not allow us to build upon its content and the key points are generated using the paper metadata rather than the full article.

  • Deep Neural Networks have led to widespread use of machine learning systems in real-world applications
  • Reliable models with accurate predictions and calibrated uncertainties are critical for decision making processes
  • Researchers propose a novel technique based on test time augmentation to improve uncertainty calibration of deep models for image classification
  • The technique comes in two variations named M-ATTA and V-ATTA and leverages an adaptive weighting system to improve uncertainty calibration without affecting the model's accuracy
  • M/V-ATTA improves uncertainty calibration by adapting weights during testing rather than training, unlike other test time augmentation approaches
  • The team evaluated the performance of the technique using different metrics of uncertainty calibration on CIFAR-10, CIFAR-100, and Aerial Image Dataset benchmarks
  • Empirical results indicate that M/V-ATTA outperforms state-of-the-art calibration techniques while maintaining baseline classification performance
  • The code for M/V-ATTA is available on GitHub at https://github.com/pedrormconde/MV-ATTA
Also access our AI generated: Comprehensive summary, Lay summary, Blog-like article; or ask questions about this paper to our AI assistant.

Authors: Pedro Conde, Tiago Barros, Rui L. Lopes, Cristiano Premebida, Urbano J. Nunes

Submitted to IEEE Transactions on Pattern Analysis and Machine Intelligence

Abstract: With the rise of Deep Neural Networks, machine learning systems are nowadays ubiquitous in a number of real-world applications, which bears the need for highly reliable models. This requires a thorough look not only at the accuracy of such systems, but also to their predictive uncertainty. Hence, we propose a novel technique (with two different variations, named M-ATTA and V-ATTA) based on test time augmentation, to improve the uncertainty calibration of deep models for image classification. Unlike other test time augmentation approaches, M/V-ATTA improves uncertainty calibration without affecting the model's accuracy, by leveraging an adaptive weighting system. We evaluate the performance of the technique with respect to different metrics of uncertainty calibration. Empirical results, obtained on CIFAR-10, CIFAR-100, as well as on the benchmark Aerial Image Dataset, indicate that the proposed approach outperforms state-of-the-art calibration techniques, while maintaining the baseline classification performance. Code for M/V-ATTA available at: https://github.com/pedrormconde/MV-ATTA.

Submitted to arXiv on 11 Apr. 2023

Ask questions about this paper to our AI assistant

You can also chat with multiple papers at once here.

The license of the paper does not allow us to build upon its content and the AI assistant only knows about the paper metadata rather than the full article.

AI assistant instructions?

Results of the summarizing process for the arXiv paper: 2304.05104v1

This paper's license doesn't allow us to build upon its content and the summarizing process is here made with the paper's metadata rather than the article.

The rise of Deep Neural Networks has led to the widespread use of machine learning systems in various real-world applications, highlighting the need for highly reliable models. To address this issue, a team of researchers have proposed a novel technique based on test time augmentation to improve the uncertainty calibration of deep models for image classification. The technique comes in two variations named M-ATTA and V-ATTA and leverages an adaptive weighting system to improve uncertainty calibration without affecting the model's accuracy. Unlike other test time augmentation approaches, M/V-ATTA improves uncertainty calibration by adapting weights during testing rather than training. The team evaluated the performance of the technique using different metrics of uncertainty calibration on CIFAR-10, CIFAR-100 and Aerial Image Dataset benchmarks. Empirical results indicate that M/V-ATTA outperforms state-of-the-art calibration techniques while maintaining baseline classification performance. The code for M/V-ATTA is available on GitHub at https://github.com/pedrormconde/MV-ATTA. The proposed approach can be useful in improving the reliability of machine learning systems used in real-world applications where accurate predictions with calibrated uncertainties are critical for decision making processes.
Created on 18 Apr. 2023

Assess the quality of the AI-generated content by voting

Score: 0

Why do we need votes?

Votes are used to determine whether we need to re-run our summarizing tools. If the count reaches -10, our tools can be restarted.

The previous summary was created more than a year ago and can be re-run (if necessary) by clicking on the Run button below.

The license of this specific paper does not allow us to build upon its content and the summarizing tools will be run using the paper metadata rather than the full article. However, it still does a good job, and you can also try our tools on papers with more open licenses.

Similar papers summarized with our AI tools

Navigate through even more similar papers through a

tree representation

Look for similar papers (in beta version)

By clicking on the button above, our algorithm will scan all papers in our database to find the closest based on the contents of the full papers and not just on metadata. Please note that it only works for papers that we have generated summaries for and you can rerun it from time to time to get a more accurate result while our database grows.

Disclaimer: The AI-based summarization tool and virtual assistant provided on this website may not always provide accurate and complete summaries or responses. We encourage you to carefully review and evaluate the generated content to ensure its quality and relevance to your needs.